| Air Speed Measurement | |
| Measurement range | 0.5 ~ 20.0 m / s |
| measurement accuracy | ± 3% of measuring + 0.2m / s accuracy may degrade during use. We recommend a regular calibration of the device. |
| Resolution | 0.1 m / s |
| Flow Measurement Performance | |
| Measurement range | 0 ~ 99999 m 3 / min. |
| units of measurement | CMM / CFM |
| Resolution | 0.1 0 - 1.0 9999.9 in the range of 10000 - 99999 |
| Temperature measurement | |
| Measurement range | -20 ° ~ + 60 ° C |
| Resolution | 0.1 ° C / ° F 0.1 |
| measurement accuracy | ± 0.6 ° C accuracy may degrade during use. We recommend a regular calibration of the device. |
| units of measurement | ° C / ° F |
| Humidity measurement | |
| Measurement range | 0.1 ~ 99.9% RH |
| Resolution | 0.1% RH |
| measurement accuracy | ± 3% for 10 - 90% RH at 25 ° C ± 5% in the other compartments accuracy may degrade during use. We recommend a regular calibration of the device. |
| units of measurement | % RH |
| Measurement of wet bulb temperature | |
| Resolution | 0.1 ° C / ° F |
| Measurement range | -20 ° C ~ + 59.9 ° C |
| Measuring memory | |
| Automatic mode | Recorder 12 000 measured values |
| Manual mode | 99 groups of measurement |
| Mechanical parameters | |
| display | LCD 54 x 37 mm, backlit |
| Dimension (H x W x D) | 180 x 58 x 25 mm |
| Weight | 200 g (excluding batteries and probe) |
| Sockets | 9V DC jack - for connecting the AC adapter jack - to transfer data to a PC |
| The probe diameter vane | 18 mm |
| telescopic boom | The arm of adjustable length in the range of 420 - 1055 mm |
| Power | |
| Batteries | 4 x 1.5V DC alkaline batteries, type AAA |
| AC adapter | AC 100-240V 50 / 60Hz / 9.0V DC 0.5A |
| Automatic power switch | After 20 minutes of inactivity, with the option to deactivate |
| Conditions of Work and Storage | |
| Working conditions | 0 ~ + 50 ° C; <80% RH noncondensing |
| storage conditions | -10 to + 50 ° C without battery; <90% RH noncondensing |
| Additional features | |
| TRIBUTE | Stop The display |
| MIN, MAX, AVG | Measuring mode values: minimum, maximum, average |
| WET BULB | Indication the evaporation temperature at the current humidity (wet bulb temperature) |
| DEW POINT | Dew point temperature display |
| Quality and Safety | |
| Electromagnetic compatibility | CE mark |
| Equipment | |
| Batteries | 4 x 1.5V DC alkaline batteries, type AAA |
| Suitcase | plastic |
| User manual | In English language |
| The cable connects to the computer | Yes |
| probe | Vane probe |
| Software | In English language |
- LCD display with backlight display option
- High sensitivity and measurement accuracy
- Interchangeable 18 mm probe vane disposed on a telescopic arm
- Simultaneous measurement of the temperature, velocity and relative humidity
- The automatic calculation of efficiency of flow and wet bulb temperature;
- Easy measurement in confined areas
- The ability to change the measuring units
- HOLD function - stop the meter display
- MAX / MIN / AVG - measurement of minimum, maximum and average
- RECORD function - memory measurements (up to 99 in manual mode and automatic mode 12000)
- Auto power off after 20 minutes, with the option to deactivate
- Built-in real time clock
- With a PC
- Socket for external 9V DC
- Ergonomic, modern design
- Software to write data to the PC
- Calibration Certificate issued by the manufacturer
Comments are closed.