With four isolated channels and up to seven hours of battery life, the lightweight THS3000 Handheld Oscilloscope Series enables you to safely make floating or differential measurements on your bench or in the field. Now you can tackle tough environments with the performance you expect from Tektronix – safely and affordably.
Key performance specifications
– 100 MHz or 200 MHz bandwidth models
– Maximum sample rates up to 5 GS/s and 200 ps resolution
– 4 fully isolated and floating channels
– 600 Vrms CAT III, 1000 Vrms CAT II rated inputs (BNC to earth ground)
| Model overview | |
| Input coupling | AC, DC |
| Input impedance | 1 MΩ ±1%, 14 pF ±2 pF |
| Input sensitivity range | 2 mV/div to 100 v/div |
| Vertical resolution | 8 bits |
| DC gain accuracy | ±2.1% of reading + 0.04 × range/div for 5 mV/div to 100 V/div |
| Max BNC input voltage | (1 MΩ) 300 Vrms CAT III from BNC signal to BNC shell |
| Max probe voltage (with standard THP0301-X probe) | 300 Vrms CAT III from 10:1 probe tip signal to BNC and reference lead |
| Trace positioning | ±4 divisions |
| Horizontal system | |
| Delay time range | 1 full screen (12 divisions) of pre-trigger or up to 100 screens (1,200 divisions) of post-trigger |
| Timing accuracy | ±100 ppm + 0.04 div |
| Zoom | Horizontally expand or compress a live or stopped waveform |
| Trigger system | |
| Input source | Oscilloscope channels 1, 2, 3, or 4. All input references isolated from each other and earth ground |
| Main trigger modes | Auto-level, Auto, Normal, and Single |
| Trigger coupling | DC, HF reject, Noise reject (reduces sensitivity) |
| Trigger sensitivity, internal DC coupled | 0.5 divisions from DC to 5 MHz at >5 mV/div THS3024: 1 division >5 MHz to 200 MHz THS3014: 1 division >5 MHz to 100 MHz |
| Trigger level range | Any channel ±4.0 divisions |
| Trigger modes | Edge: Positive, negative, or dual slope on any input channel. Coupling includes DC, HF reject, and Noise reject Pulse width: Trigger on channel 1, width of positive or negative pulses (glitches) that are >, <, =, or ≠ a specified period of time (resolution of 0.01 div with minimum time of 50 ns) Event: Trigger on n-th occurrence of trigger (N selectable from 2 to 99) Video: Trigger on channel 1, line number, all lines, odd, even, or all fields on NTSC, PAL, PAL plus, and SECAM signals Non-interlaced: Trigger on channel 1, high-res non-interlaced video with line frequencies from 14 kHz to 65 kHz |
| Acquisition modes | |
| Sample (default) | Acquire sampled values |
| Glitch detect | Captures high frequency or glitches as narrow as 8 ns from 5 μs to 120 s/div |
| Averaging | Selectable from 2, 4, 8, or 64 waveforms |
| Roll | Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 4 ms/div |
| Data recorder | Automatic data logging of 100 triggered records (screens) with date and time stamp. store internally or to a USB device |
| Waveform compare | Visually compare against user-definable reference waveforms or perform automatic pass or fail testing of 1 to 4 oscilloscope channels with data logging of test results |
| Automatic setup | |
| Autoset | Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems |
| Autorange | Continuous auto-setup of vertical, horizontal, and trigger systems that track signal changes |
| Waveform measurements | |
| Cursors | Time, freq (1/T), volts, watts, Rise/Fall time from any input channel or math waveform |
| Automatic measurements | 21. Up to 4 can be displayed on-screen at any one time. Measurements include: V DC, V ACRMS, V AC+DC, VPeakMax, VPeakMin, Peak to Peak, A DC, A AC, A AC+DC, Frequency, Rise time (using cursors), Fall time (using cursors), Phase (between any 2 inputs), Positive pulse width, Negative pulse width, Positive duty cycle, Negative duty cycle, dBV, dBm into 50 Ω and 600 Ω |
| TrendPlot™ | Records and graphically displays any 4 automatic measurements. store internally or to USB flash drive for recall and analysis |
| Waveform math | |
| Arithmetic | Add, subtract, and multiply waveforms |
| FFT | Spectral magnitude. Set FFT vertical scale to Linear or Logarithmic, and FFT window to Automatic, Hamming, Hanning, or None |
| Display system | |
| Display type | 6 in. (153 mm) liquid-crystal color display |
| Display resolution | 320 horizontal × 240 vertical pixels |
| Waveform style | Vectors (dot-join), Dots, Envelope, Variable persistence, Infinite persistence |
| Display format | YT and XY |
| Storage memory | |
| Reference | 4 user-definable reference traces |
| Waveform | Stores 30 internal oscilloscope records (4 traces each) with screen image and corresponding setup |
| Recording | Store 10 internal recordings that can be a 100-screen replay sequence, a roll-mode recording, or a TrendPlot™ measurement recording |
| Screen image | Store up to 9 internally or 256 .bmp images to an external USB storage drive1 |
| 1Maximum USB memory size supported is 2 GB | |
| Real-time clock | Time and date stamp of all stored data |
| Input/Output ports | |
| USB host port | Supports USB mass storage devices |
| USB device port | Mini USB-B connector allows for communication/control of oscilloscope |
| Probe compensator output | Side-panel output Amplitude: 1.225 Vp-p Frequency: 500 Hz |
| Kensington-style lock | Side-panel security slot connects to standard Kensington-style lock |
| Software | |
| OpenChoice® Desktop | Enables fast and easy communication between a Windows PC and the THS3000 Series. Transfer and save settings, waveforms, and screen images. |
| Power source | |
| Battery | 7 hour, 10.8 V rechargeable Li-Ion battery |
| Battery charging time | 5 hours |
| Line power | AC power adapter/charger |
| Power source voltage | 100 V to 240 V AC ±10% |
| Power source frequency | 50 Hz to 60 Hz |
| Physical characteristics | |
| Dimensions | Height: 265 mm (10.5 in.) Width: 190 mm (7.5 in.) Depth: 70 mm (2.8 in.) |
| Weight | Net: 2.2 kg (4.8 lb.) Shipping (base model): 4.7 kg (10.4 lb.) Shipping (TK model): 7.8 kg (17.1 lb.) |
| Environmental | |
| Enclosure | IP 41 according to IEC60529S |
| Temperature | Operating 0 °C to +45 °C (with battery) 0 °C to +50 °C (without battery) Nonoperating –20 °C to +60 °C |
| Humidity | Operating: 0 °C to 10 °C, noncondensing 10 °C to 30 °C, up to 95% relative humidity 30 °C to 40 °C, up to 75% relative humidity 40 °C to 50 °C, up to 45% relative humidity Nonoperating: –20 °C to 60 °C, relative humidity, noncondensing |
| Altitude | Operating: Up to 3,000 m (9,843 ft.) Nonoperating: Up to 12,000 m (39,370 ft.) |
| Vibration/Shock | Operating: Vibration (Sinusoidal): 3 g max, according to MIL-PRF-28800F, class 2 Shock: 30 g max, according to MIL-PRF-28800F, class 2 Nonoperating: Vibration (Random): 0.03 g2/Hz, according to MIL-PRF-28800F, class 2 |
| Regulatory | Electromagnetic compatibility: EN 61326-1:2006, EN 61326-2-1:2006 for emission and immunity Safety: UL61010-1:2004; CAN/CSA C22.2 No. 61010.1-04; EN61010-1:2001, Pollution degree 2; ANSI/ISA-82.02.01 |
- 21 automatic measurements
- Waveform math and FFT spectral analysis
- Volts, time, frequency, watts cursor measurements
- Measurement data logging with TrendPlot™
- Waveform pass/fail limit testing
- Automatic 100 display screens recorder
- 6 in. (153 mm) bright color display
- USB device and host support 1
- 7 hours of continuous battery operation