TK4830 is an AC & DC integrated EVSE verification device. The device accuracy of AC & DC energy measurement reaches Class 0.1, and it can complete the working error and clock time error test of AC & DC EVSE.
|
DC Measurement Function |
|||||
|
DC Voltage |
Measuring Range |
30 V~1150 V |
|||
|
Measurement Uncertainty (k=2) |
0.05%*RD |
||||
|
DC Current |
Measuring Range |
1 A~300 A [1] |
|||
|
Measurement Uncertainty(k=2) |
5 A ≤ I ≤ 300 A |
0.05%*RD |
|||
|
1 A ≤ I <5 A |
0.1%*RD |
||||
|
Power/Energy |
Measurement Uncertainty(k=2) |
5 A ≤ I ≤ 300 A |
0.1%*RD |
||
|
1 A ≤ I <5 A |
0.15%*RD |
||||
|
AC Measurement Function |
|||||
|
AC Voltage |
Measuring Range |
Phase voltage 30 V~300 V |
|||
|
Measurement Uncertainty (k=2) |
0.05%*RD |
||||
|
AC Current |
Measuring Range |
Three-phase 0.1 A~80 A[1] |
|||
|
Measurement Uncertainty(k=2) |
Three-phase 0.1 A~80 A |
0.05%*RD |
|||
|
Power/Energy |
Measurement Uncertainty(k=2) |
Three-phase 0.1 A~80 A |
0.1%*RD |
||
|
Clock Function |
|||||
|
Clock |
Timing mode |
GPS Clock timing |
|||
|
Time Error |
≤ 1 s |
||||
|
Temperature Function |
|||||
|
Temperature |
Measurement Range |
-30 ℃~60 ℃ |
|||
|
Maximum Permissible Error |
0.5 ℃ |
||||
|
Note [1]: If the gun line output Max. Current is lower than measurement range, the maximum measurement current will be based on the output current of the gun line. |
|||||