A significant addition to the comprehensive range of Megger Low Resistance Ohmmeters, DLRO100 enables low resistance measurement, across multiple applications, in areas without access to mains power. The integral Li-Ion battery supplies a constant 100 A current for up to 200 Manual/Auto tests to enable enhanced productivity in remote locations. With a focus on user safety, advanced design features ensure the safe operation of the instrument in the most adverse conditions, including a CAT IV 600 VAC / 500 VDC safety rating in accordance with IEC61010. The rugged design, intuitive interface and IP54 (lid open) rating ensure reliability and ease of use in the most arduous of conditions.
| DLRO100 | ||||
|---|---|---|---|---|
| FEATURES | EB | XB | HB | BENEFITS |
| CAT IV 600 V AC / 500 V DC up to 2000 m CAT IV 300 V up to 4000 m | On all test terminals for safe operation | |||
| Lightweight 100 A battery powered unit | Easily portable – 7.9 Kg (17 lbs) with battery | |||
| High noise immunity | For stable readings in noisy environments | |||
| Smooth DC Output | Circuit breaker testing | |||
| IP54 Lid open IP65 Lid closed |
For protection against ingress during operation (lid open) and storage (lid closed) |
|||
| Li-ion battery | Always ready to test with a Li-ion fast charge battery – 2.5 hours charge time from fully discharged Works from an AC supply if the battery is fully discharged Battery capacity – 200 single tests or up to 2x 10 minutes continuous 100 A output for extended use |
|||
| 100A Manual, Auto and Continuous test |
Quick selection of test modes for different applications with 4 terminal measurement for flexibility |
|||
| Custom test | Adjustable current 10 – 110 A, ramp rates configurable from 0.5s upto 30s and configurable test duration for flexibility |
|||
| Range and test mode rotary switches |
Quick and easy selection of current ranges and test modes | |||
| Ultra tough outer case construction | Designed for use in demanding environments with a flame retardant UL94 V0 inner case for safety | |||
| Dual Ground™ | * | * | Using the optional DC clamp enables circuit breaker testing with ground protection in place for safety | |
| Large, clear LCD | Ideal for all light conditions, with backlight | |||
| Internal memory storage with USB download capability | For effective results management, up to 220 time and date stamped records | |||
| Remote Control | Control the instrument remotely over USB via a PC or laptop for added safety | |||
| Asset tagging | Running a PowerDB app on Windows tablet or smart phone to populate unique asset IDs for efficient asset management | |||
| Bluetooth® | For effective wireless communication. For download and asset tagging | |||
| * with optional Clamp | ||||
Test Modes
The Manual test mode allows the user to initiate the test procedure once the probes are in contact with the object under test. Once the TEST button is depressed the TEST lamp will illuminate and the instrument will undertake a single test to verify the resistance of the test object.
In Auto mode the user selects the desired current, connects the current test leads and as soon as the potential leads are connected a test will start automatically. To repeat a test, simply break contact with the potential probes and remake contact.
In Continuous mode the user connects the test leads and presses the TEST button, initiating the test procedure. The instrument will continue to test, updating the display after each new test cycle, until the TEST button is pressed or the test procedure times out.
A new tough adjustable clamp has been designed to ensure flexibility in many applications and provides a good connection with the test piece.
Test Leads:
Standard test leads, with separate Current & Potential, or Kelvin, combining both Current & Potential in one clamp, are available as optional accessories in 5 m, 10 m & 15 m lengths. All test leads are CAT IV 600 V AC / 500 V DC safety rated.
Comments are closed.